Views: 0 Author: Site Editor Publish Time: 2022-07-07 Origin: Site
1. Check whether the steam trap is faulty. If there is a fault, repair or replace it in time after the steam curing is completed;
2. Check whether the water-repellent cover in the kettle is blocked, and clean the debris on the lower part of the kettle and the filter cover frequently to ensure smooth drainage;
In addition, it should be noted that when the amount of condensed water in the initial stage of boosting is large and the discharge of the steam trap is insufficient, the drain valve should be opened in time to accelerate the discharge of condensed water, so as to avoid too much condensed water in the autoclave and cause the temperature difference between the upper and lower walls of the autoclave to be too large. , causing the autoclave to arch and deform, affecting the service life of the autoclave.
Our autoclave is equipped with two sets of wall temperature measuring thermometers, which are located at the top and bottom of the kettle. The measurement results are transmitted to the electric control cabinet in real time. Check the condensate discharge system, and open the manual drain valve if necessary to speed up the condensate discharge.
The automatic sewage system developed by our company in recent years has achieved automatic discharge of condensed water through liquid level control without manual intervention.Ensure that the condensed water in the kettle is discharged in time, improve the service life of the autoclave, and ensure the quality of steam curing.