Large-scale circulating fluidized bed boilers, gas boilers, biomass boilers, waste heat boilers for waste, hazardous waste, non-ferrous metals, CDQ and other waste heat boilers, R&D and manufacturer of new intelligent control autoclaves
Boiler specifications
Home » News Center » Boiler knowledge » Boiler specifications

Boiler specifications

Views: 2111     Author: Site Editor     Publish Time: 2024-06-13      Origin: Site


There is no refractory brick wall in the furnace of corner tube boiler, which is heated evenly. The membrane water-cooled wall produced by international standard, which has small thermal stress and fast heat transfer. Therefore, this type of boiler has rapid start-up, rapid temperature rise and strong adaptability to load change. There is no refractory brick wall structure in the furnace, which reduces a large amount of heat storage. The grate frame is reasonably designed, especially the cast iron structure is used in front of the frame supporting the driving shaft, which effectively ensures that the driving shaft will not shift locally under various loads. The whole boiler is welded together by the membrane water-cooled wall, and the ball which can be freely shifted is installed at a certain angle at the pivot point on one side of the boiler, which can avoid the damage of thermal stress caused by the thermal expansion and contraction of the boiler.


The boiler specification indicates the ability and level of the boiler to produce steam or heating water. The specification of a steam boiler is expressed in terms of the amount of steam generated per unit time and steam parameters, while the specification of a hot water boiler is expressed in terms of the heat absorption amount of water per unit time and hot water parameters.

The amount of steam generated by a steam boiler per hour is called the boiler's evaporation capacity, also known as the boiler's capacity or output. It is usually represented by the symbol "D", and the unit is t/h. The evaporation capacity on the boiler nameplate is usually the rated evaporation capacity, which is the maximum evaporation capacity that must be guaranteed during continuous operation of the boiler under specified steam parameters and feedwater temperature.

The capacity of a hot water boiler is the amount of heat absorbed by water in the boiler per unit time, in MW, and its rated value is called rated thermal power or rated heat supply.

The amount of steam produced and heat absorbed by the medium in the boiler is directly related to the number of heating surfaces in the boiler. The heating surface is a metal wall in a boiler that separates flue gas and water vapor and transfers heat from the former to the latter, usually a tube or cylinder wall.

The steam parameters of a steam boiler are expressed by the pressure (gauge pressure) and temperature of the steam at the outlet of the main steam valve of the boiler. The medium parameters of a hot water boiler are expressed in terms of rated outlet pressure and rated outlet/inlet temperature. Pressure and temperature are indicated by the symbols "p" and "t", respectively.


危废、固废焚烧余热锅炉02


The above is Jiangsu Sifang Clean Energy Equipment Manufacturing's answer to this question. If you have any questions about other boiler related issues, please consult Jiangsu Sifang Clean Energy Equipment Manufacturing's online customer service or call 0516-85871846 or 0516-85532705. Jiangsu Sifang Clean Energy Equipment Manufacturing's professional technicians will answer your questions in time.

Integrate high-end technology to create high-quality boilers

Product Center

Quick Links

Services

Contact us
+86 0516 85888039
Whatsapp: +86 19805005735
E-mail: xxb@jssfgl.com
 
Huarun Industrial Park, Xuzhou Huaihai International Port District, Xuzhou City, Jiangsu Province, China
Copyright 2023 Jiangsu Sifang Clean Energy Equipment Manufacturing Co.,Ltd | Sitemap    苏ICP备14011720号-1